Quality and safety
Each plant has its own test laboratory, and no batch goes to the warehouse without a test report. The report goes to the customer with the goods.

Test laboratories
Murov Metal, Sumgait
- Tensile and bend tests up to 600 kN
- Impact toughness down to −40 °C
- Ultrasonic and magnetic-particle testing of welds
- Zinc coating thickness and adhesion
Murov Kabel, Sumgait
- High-voltage test up to 100 kV
- Partial discharge measurement
- Conductor resistance
- Insulation and sheath thickness, hot-set test
Murov Polimer, Ganja
- Hydrostatic pressure test: 165 hours at 80 °C
- Melt flow rate (MFR)
- Oxidation induction time (OIT)
- Elongation at break and weld joint tests
Health, safety and environment
In 2025 the three plants recorded 2 lost-time incidents in 2.1 million hours worked. Every new employee completes 16 hours of training before going onto the shop floor, and welders and crane operators are re-examined once a year.
Steel scrap and polymer offcuts all go back into recycling. Waste water from the galvanising shop is neutralised and reused; none of it goes to the city sewer.
- Lost-time injury frequency rate (LTIFR), 2025
- 0.95
- Safety training, 2025
- 14,200 hours
- Production waste recycled
- 94 per cent
- Rooftop solar plant, Ganja
- 1.2 MW

Certificates
The certificates were issued by accredited independent bodies. We send a copy within one working day of your request.
| Standard | Scope | Held by | Number | Valid until |
|---|---|---|---|---|
| ISO 9001:2015 | Quality management: all group companies | Group | QMS-AZ-04417 | |
| ISO 14001:2015 | Environmental management: the three plants | Group | EMS-AZ-02093 | |
| ISO 45001:2018 | Occupational health and safety: the three plants and logistics | Group | OHS-AZ-01865 | |
| EN 1090-2, EXC3 | Fabrication of steel structures, CE marking | Murov Metal | FPC-1090-2291 | |
| ISO 3834-2 | Quality requirements for fusion welding | Murov Metal | WLD-3834-0778 | |
| IEC 60502-2 | Type tests for 6–35 kV XLPE cable | Murov Kabel | TT-MV-2019-116 | |
| EN 12201-2 | PE100 water pipe, Ø20–630 mm | Murov Polimer | PE-W-3306 | |
| EN 1555-2 | PE100 gas pipe, Ø20–315 mm | Murov Polimer | PE-G-3307 |