Skip to main content
MurovIndustrialGroup

Quality and safety

Each plant has its own test laboratory, and no batch goes to the warehouse without a test report. The report goes to the customer with the goods.

The test laboratory with tensile machines

Test laboratories

Murov Metal, Sumgait

  • Tensile and bend tests up to 600 kN
  • Impact toughness down to −40 °C
  • Ultrasonic and magnetic-particle testing of welds
  • Zinc coating thickness and adhesion

Murov Kabel, Sumgait

  • High-voltage test up to 100 kV
  • Partial discharge measurement
  • Conductor resistance
  • Insulation and sheath thickness, hot-⁠set test

Murov Polimer, Ganja

  • Hydrostatic pressure test: 165 hours at 80 °C
  • Melt flow rate (MFR)
  • Oxidation induction time (OIT)
  • Elongation at break and weld joint tests

Health, safety and environment

In 2025 the three plants recorded 2 lost-time incidents in 2.1 million hours worked. Every new employee completes 16 hours of training before going onto the shop floor, and welders and crane operators are re-examined once a year.

Steel scrap and polymer offcuts all go back into recycling. Waste water from the galvanising shop is neutralised and reused; none of it goes to the city sewer.

Lost-time injury frequency rate (LTIFR), 2025
0.95
Safety training, 2025
14,200 hours
Production waste recycled
94 per cent
Rooftop solar plant, Ganja
1.2 MW
Sparks from welding

Certificates

The certificates were issued by accredited independent bodies. We send a copy within one working day of your request.

Certificates
ISO 9001:2015Quality management: all group companiesGroupQMS-AZ-04417
ISO 14001:2015Environmental management: the three plantsGroupEMS-AZ-02093
ISO 45001:2018Occupational health and safety: the three plants and logisticsGroupOHS-AZ-01865
EN 1090-2, EXC3Fabrication of steel structures, CE markingMurov MetalFPC-1090-2291
ISO 3834-2Quality requirements for fusion weldingMurov MetalWLD-3834-0778
IEC 60502-2Type tests for 6–35 kV XLPE cableMurov KabelTT-MV-2019-116
EN 12201-2PE100 water pipe, Ø20–630 mmMurov PolimerPE-W-3306
EN 1555-2PE100 gas pipe, Ø20–315 mmMurov PolimerPE-G-3307
Ask for a copy of a certificate
Call usGet a quote